|
Advance Flood Protection
and Ventilation Foundation
Flood Vents
Potential to Dramatically Reduce
Your NFIP Insurance Premiums
Protect your Home With Proven
Venting Technology
Code Compliant, FEMA Accepted
ICC Certified
Virtually Indestructible 100%
Stainless Steel Design
World’s FIRST and ONLY ICC Certified
Automatic Foundation Flood Vents
|

|
ICC CERTIFIED to the building code requirements of the ICC, IRC, BOCAI, SBCCI, and ICBO. Also conforms to the flood insurance requirements of FEMA and the National Flood Insurance Program for automatic relief of hydrostatic pressure on the foundation walls due to rising or falling floodwaters. FEMA and the NFIP require this feature for all buildings located within a floodplain or areas prone to flooding. The all STAINLESS STEEL construction meets or exceeds all flood and corrosion resistance code requirements and the REMOVABLE flood door allows for easy cleaning. As a Partner in Mitigation with FEMA Region II, and an American Institute of Architects Continuing Education credit provider for Health, Safety, and Welfare we are dedicated to education and code compliance.
|
 |
Three Models are Available:
|
|
Smart VENT®: Used when Flood protection and
ventilation are both required.
- Louvers and screen automatically rotate out of the path of flood water, providing the required 3” diameter of completely unobstructed open area for flood water to enter and exit.
- Temperature controlled louvers automatically open in warm weather and close in cold
- Provides 50 sq inches of net free area for air ventilation, temperature control and radon evacuation
- Easy-to-clean rodent and vermin-resistant screen
Click Here for More Information on Smart Vent®
|

Smart VENT
Model 1540-510
|
|
|
Flood VENT: Used when one needs flood protection, but does not need or want ventilation
- Insulated door minimizes heat or air conditioning loss from entries and garages
- Ideal for retrofit into a utilized space
- Weather strip sealing keeps out air and insects
Click Here for More Information on Flood Vent®
|
Flood VENT
Model 1540-520
|
|
|
Overhead Door VENT: Mounted in an overhead garage door.
- The vent can be placed in a standard overhead garage door.
- The easiest way to add vents and comply to NFIP flood vent requirements
- Used when wall space is at a minimum, as in a townhouse or condominium
- Insulated door minimizes heat or air conditioning loss from entries and garages
- Two vents provides 400 square feet of flood protection
- Ideal for retrofit into an existing garage door.
Installation is easy and all hardware is included
|
Overhead Door
VENT
Model 1540-524
|
Click Here for More Information on Over Head Door Vent®
|
|
|
|
All Models have the following features:
|
|
- 8”x16” vents are certified as an engineered opening to cover 200 sq. ft of enclosed area below flood level
- Easily stackable to a 16” X 16” configuration for 400 Sq. Ft of coverage in one opening.
- Provides automatic entry and exit of floodwaters to relieve hydrostatic pressure
- Two patented floats automatically release with rising water and open the Bi-directional flood door
- Flood door automatically rotate out of the path of flood water, providing the required 3” diameter of completely unobstructed open area for flood water to enter and exit.
- Stainless steel construction- Made in the USA-
|
|
|
|
Additional Information available in PDF format
|
|
|
Click Here for Smart Vent Product Summary
Click Here for Smart Vent Garage Door Vent Installation
Click Here for Smart Vent Product Spec Sheet
Click Here for Smart Vent Product Warranty
|
|
|
|